ID Inspection Inspection Item Response Value Outcome Comments
1 GEO-INSP-2026-000101 TPL-REENTRY-WALL item 1 YES PASS Radar active, no standing alarm at start of inspec...
2 GEO-INSP-2026-000101 TPL-REENTRY-WALL item 2 YES FAIL New ~12m tension crack at crest, not present on 18...
3 GEO-INSP-2026-000101 TPL-REENTRY-WALL item 3 35 PASS_WITH_ACTION Max aperture 35mm, opening since last reading.
4 GEO-INSP-2026-000101 TPL-REENTRY-WALL item 4 YES PASS_WITH_ACTION Seepage on lower batter after rainfall.
5 GEO-INSP-2026-000101 TPL-REENTRY-WALL item 5 DETERIORATING FAIL Access classified deteriorating; restriction requi...
6 GEO-INSP-2026-000102 TPL-BENCH-PRESHIFT item 1 YES PASS Catch bench clear.
7 GEO-INSP-2026-000102 TPL-BENCH-PRESHIFT item 2 YES PASS_WITH_ACTION Minor loose material; scaling scheduled.
8 GEO-INSP-2026-000102 TPL-BENCH-PRESHIFT item 3 YES PASS Barrier intact.